HP XP P9000 Remote Web Console Messages (AV400-96604, January 2014)
Table 60 Error codes (part code 06610) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WAll journals are used by Universal Replicator for
z/OS or Continuous Access Journal. If possible,
There are no valid journals.05904206610
delete the journals for Universal Replicator for
z/OS or Continuous Access Journal, then start
the Universal Replicator for z/OS window or the
Continuous Access Journal window.
WReduce the number of journal volumes to be
registered, or increase the number of journal
volumes to be deleted.
The number of journal volumes in some
journals exceeds the maximum.
Adjust the number of journal volumes.
05904306610
WUse the sort function to identify volumes with the
same LDKC number, the same CU number and
the same LDEV number.
The same volume is stored more than
once in the Preview list.
Please use the sort function to identify
volumes with the same LDKC number,
05910006610
the same CU number and the same LDEV
number.
WCreate a volume that can be used as a journal
volume. To do this, add a volume or use some
other way.
There is no volume that can be
registered or deleted.
05910306610
WSpecify a different CU or parity group.The specified CU or parity group does
not contain volumes that can be
registered or deleted as journal volumes.
05910406610
WCheck the CLPR number of the specified volume
and the CLPR numbers of volumes if it is already
Multiple CLPR numbers are existing in
the specified volume, or you tried to
05911306610
existed. Specify a volume so that there is only one
CLPR number in the journal.
register a volume different from the CLPR
number of an existing volume. In one
journal, more than one CLPR numbers
cannot be existed.
WCheck the amount of the Preview data. If the
amount of the Preview data is too large, clear the
The number of Preview data may have
exceeded the limit, or too large number
of data is selected.
05911506610
Preview data by clicking [Apply], and then retry
the operation.
If the amount of Preview data is small or there is
no Preview data, too much data is selected.
Reduce the number of data, and retry the
operation.
WCheck the microcode version of the DKCMAIN,
then contact HP Technical Support.
The specified function is not supported
by the current microcode version.
05911606610
WCheck the microcode version of DKCMAIN. To
use other emulation types, please contact HP
The current microcode version of
DKCMAIN does not support Add Pair
05915006610
Technical Support to update the microcode
version of DKCMAIN.
(Paircreate) operations, Resume Pair
operations, and Change Pair Option
operations using the emulation type of
the specified volume.
WTo use a mainframe volume as a journal volume,
please contact HP Technical Support to update
the microcode version of DKCMAIN.
The current microcode version of
DKCMAIN only supports OPEN-V as the
emulation type of a journal volume.
05915106610
WCheck the emulation type of the specified volume.There are two or more kinds of
emulation types that cannot be
05915206610
combined, in the specified volume. Or
you tried to add a volume which cannot
be combined with the emulation type of
the existing volume.
Part code 06610 243