HP XP P9000 Remote Web Console Messages (AV400-96604, January 2014)

Table 60 Error codes (part code 06610) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WTo delete the specified storage system, click [OK].
Otherwise, click [Cancel].
Are you sure you want to delete the
specified storage systems?
05900706610
WTo delete the specified path, click [OK].
Otherwise, click [Cancel].
Are you sure you want to delete the
paths of the specified storage system?
05900806610
WClick [OK]. Apply the preview data to the storage
system, then retry the operation.
Since the number of preview data
exceeded the maximum, the excess data
05900906610
were discarded. No more preview data
can be stored.
iCheck the contents of the primary and secondary
volumes. If the contents match, click [Yes].
Otherwise, click [No].
WARNING:
Initial copy mode "None" is selected for
some volume pair. Are you sure that the
05901006610
primary data volume and the secondary
data volume of the pair are already
synchronized?
iTo output the file, click [Yes]. Otherwise, click
[No].
Are you sure you want to output the %s
file?
05901106610
WTo overwrite the file, click [Yes]. Otherwise, click
[No].
The specified file already exists. Do you
want to overwrite this file?
05901306610
WCheck the parameters of DKC setting.You are going to set the same DKC more
than once.
05902606610
WTo continue the operation, click [OK]. To cancel
the operation, click [Cancel].
The monitoring data saved at present
will be deleted.
05903006610
The current monitoring data will be deleted if you
change the setting of the monitoring switch. If
necessary, use the Performance Monitor Export
Tool to export the monitoring data file.
WTo continue processing, click [OK]. To stop
processing, click [Cancel].
The monitoring data being saved at
present is deleted when the monitoring
switch is set to Enable at the next time.
05903106610
If the currently saved monitoring data is needed,
use the export tool to save the data.
WPurchase a license for Continuous Access Journal
Z, then install it.
You cannot add journal volumes
because Continuous Access Journal Z is
not installed.
05904006610
WTo delete the journal volume, click [Yes].
Otherwise, click [No].
Warning:
A mainframe volume is included in the
journal volumes to be deleted.
05904106610
HP recommends that you record the LDKC
number, the CU number and the LDEV number of
the mainframe volume.
Note the following points if you have
made volume pairs by using this journal
before.
The mainframe volume will be
blocked.
The mainframe volume needs to be
formatted when you use the volume
as a non-journal volume.
The LDKC number, the CU number
and the LDEV number of the
mainframe volumes are
recommended to be recorded.
Do you want to continue the operation?
242 Messages (part code group 06nnn)