HP XP P9000 Remote Web Console Messages (AV400-96604, January 2014)
Table 57 Error codes (part code 06505) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
ECheck the capacity of shared memory of the
primary storage system.
The Add Pair (Paircreate) operation
failed because the capacity of shared
06800806505
memory of the primary storage system
was insufficient.
ECheck the remote storage system's shared memory
capacity.
The Add Pair (Paircreate) operation
failed because the capacity of shared
06800906505
memory of the remote storage system
was insufficient.
WCheck the status of the specified journal.The specified journal cannot be added
to extended consistency group (EXCTG),
06801006505
because the specified journal is not
registered, or the status of the specified
journal is "Initial."
WCheck whether the specified volume is a Thin
Provisioning volume.
The operation failed because the
specified volume was a Thin Provisioning
or Thin Provisioning Z volume.
06801306505
WCheck whether the specified volume is a pool
volume of Thin Provisioning.
The operation failed because the
specified volume was a pool volume of
Thin Provisioning.
06801406505
WCheck if the volume specified as the primary data
volume is a Thin Provisioning volume.
The operation failed because the volume
specified as the primary data volume is
a Thin Provisioning volume.
06801506505
WCheck if the volume specified as the primary data
volume is a pool volume of Thin Provisioning.
The operation failed because the volume
specified as the primary data volume is
a pool volume of Thin Provisioning.
06801606505
WCheck if the volume specified as the secondary
data volume is a Thin Provisioning volume.
The operation failed because the volume
specified as the secondary data volume
is a Thin Provisioning volume.
06801706505
WCheck if the volume specified as the secondary
data volume is a pool volume of Thin Provisioning.
The operation failed because the volume
specified as the secondary data volume
is a pool volume of Thin Provisioning.
06801806505
WCheck whether the secondary storage system
supports the LDEV number of the specified primary
data volume.
The secondary storage system does not
support the LDEV number of the specified
primary data volume.
06801906505
WCheck the connected storage system's microcode
version.
The operation failed because the current
microcode version does not support
Delta Resync.
06802406505
WInstall the Cont Access Journal 3DC & 4x4 Open
MF function in the primary storage system.
The volume specified as the primary
data volume is used as a pair volume of
06802506505
Continuous Access Synchronous,
External Storage Access Manager, or
Continuous Access Synchronous Z. The
operation failed because the Cont
Access Journal 3DC & 4x4 Open MF
function is not installed in the primary
storage system.
WInstall the Cont Access Journal 3DC & 4x4 Open
MF function in the secondary storage system.
The volume specified as the secondary
data volume is used as a pair volume of
06802606505
Continuous Access Synchronous,
External Storage Access Manager, or
Continuous Access Synchronous Z. The
operation failed because the Cont
Access Journal 3DC & 4x4 Open MF
Part code 06505 221