HP XP P9000 Remote Web Console Messages (AV400-96604, January 2014)
Table 54 Error codes (part code 06005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WInstall the External Storage Access Manager
function to the RCU.
The Paircreate operation failed because
the External Storage Access Manager
function was not installed in the RCU.
6879006005
WRefresh the window, and confirm whether the
specified volume is an R-VOL.
The operation failed because the
specified volume was not an R-VOL.
06879106005
WRefresh the window, and confirm whether the
specified volume is an External Storage Access
Manager pair volume.
The operation failed because the
specified volume was not an External
Storage Access Manager pair volume.
06879206005
WRefresh the window, and confirm whether the
status of the specified volume is SSWS.
The Reverse Resync operation failed
because the status of the specified
volume was not SSWS.
06879306005
WCreate a path from the RCU to the MCU.The operation failed because the path
from the RCU to the MCU did not exist.
06879406005
EContact HP Technical Support, and check the
shared memory.
The operation failed. The shared
memory might be insufficient.
06879506005
Please contact HP Technical Support.
WRefresh the window, and confirm the pair status
of the specified volume.
The operation failed. The operation
cannot be accepted in the pair status of
the specified volume.
06879606005
WCheck each capacity of the M-VOL and the R-VOL
after the capacity change of R-VOL ends, and
plan a combination of volumes for pair creating.
A pair could not be created because the
specified R-VOL was a Thin Provisioning
volume or Thin Provisioning Z volume
whose capacity was being changed.
06881206005
WCheck each capacity of the M-VOL and the R-VOL
after the capacity change of M-VOL ends, and
plan a combination of volumes for pair creating.
A pair could not be created because the
specified M-VOL was a Thin Provisioning
volume or Thin Provisioning Z volume
whose capacity was being changed.
06881306005
WThe specified volume is a primary data volume
of the Continuous Access Journal, which runs on
A pair cannot be created because the
specified volume is used as a primary
06881606005
the 2DC configuration in which the Continuousdata volume of the Continuous Access
Journal. Access Synchronous or External Storage Access
Manager cooperates. Specify another volume.
WThe RCU runs on the 2DC configuration in which
the Continuous Access Journal cooperates.
The specified R-VOL was a pair volume
of the Continuous Access Journal.
06881706005
Set "Track" to the "Difference Management," then
retry the operation.
A pair could not be created because
"Cylinder" was set to the "Difference
Management."
WInstall the External Storage, then retry the
operation.
The operation failed, because the
External Storage function was not
installed.
06882606005
176 Messages (part code group 06nnn)