Table 53 Error codes (part code 05310) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
EIf the problem persists despite retrying, please
contact HP Technical Support.
Configuration information is not correct.00742705310
iTo continue processing, click [OK]. To stop
processing, click [Cancel].
Are you sure you want to delete the
WWN?
00907705310
iTo continue processing, click [OK]. To stop
processing, click [Cancel].
Are you sure you want to delete the
Performance Control group?
00907805310
iTo continue processing, click [OK]. To stop
processing, click [Cancel].
The Performance Control group is
deleted because no WWN is registered
in the Performance Control group.
00907905310
WClick [OK].The control status will change to "Port
Control."
00931205310
WClick [OK].The control status will change to "WWN
Control."
00931305310
WSet up a maximum value to enable the control.The control status will change to "No
Control" because the upper value is 0
for all ports.
00931405310
iIf you use the real time option for the first time,
turn the monitoring switch ON.
The monitoring switch is turned OFF.00931505310
WIf you accept the change in the control status to
"No Control", continue the operation.
The control status will change to "No
Control."
00932605310
WTo clear the settings, check the check box of
"Delete ports if CHA is removed," and then click
[Apply].
The settings for the removed ports
remain.
00932805310
WIf you click [OK] on the next window, the settings
on port control will be initialized. To quit the
operation, click [Cancel] on the next window.
Next, the initialization for the settings
on port control will be executed.
00932905310
WIf you click [OK] on the next window, the settings
on WWN control will be initialized. To quit the
operation, click [Cancel] on the next window.
Next, the initialization for the settings
on WWN control will be executed.
00933005310
WCorrect the specified contents, and request the
setting of the configuration information again.
The specified WWN is already in use.00933105310
iClick [Yes] to change the control status.Do you want to change the control status
to Port Control?
00933305310
iClick [Yes] to change the control status.Do you want to change the control status
to WWN Control?
00933405310
iClick [Yes] to change the control status.Do you want to change the control status
to No Control?
00933505310
iTo continue processing, click [OK]. To stop
processing, click [Cancel].
The Performance Control group extends
across multiple SLPRs. Do you want to
continue?
05900005310
iReduce the number of WWNs to be monitored,
which exceeds the maximum, and then retry the
operation.
WWN cannot be registered because
the number of WWNs of one of the
ports to be monitored at the same time
exceeds the maximum.
06573305310
Part code 05310 157