HP XP P9000 RAID Manager Installation and Configuration User Guide (T1610-96046, August 2012)
HORCM_DEV
#dev_group dev_name port# TargetID LU# MU#
VG01 oradb1 CL1-H 0 2 0
VG01 oradb2 CL1-H 0 4 0
VG01 oradb3 CL1-H 0 6 0
HORCM_INST
#dev_group ip_address service
VG01 HOSTB horcm1
FOR horcm1.conf
HORCM_DEV
#dev_group dev_name port# TargetID LU# MU#
VG01 oradb1 CL1-H 0 3 0
VG01 oradb2 CL1-H 0 5 0
VG01 oradb3 CL1-H 0 7 0
HORCM_INST
#dev_group ip_address service
VG01 HOSTA horcm0
(7) Start ‘horcmstart 0 1’.
The subprocess (HORCM) created by bash is terminated when the bash is EXIT.
bash$ horcmstart 0 &
19
bash$
starting HORCM inst 0
bash$ horcmstart 1 &
20
bash$
starting HORCM inst 1
Using CCI with Hitachi and other storage systems
Table 11 (page 29) shows the related two controls between CCI and the RAID storage system type
(Hitachi or HP XP). Figure 6 (page 30) shows the relationship between the application, CCI, and
RAID storage system.
Table 11 Relationship between CCI and RAID storage system
XP API/CLICommon API/CLIRAID systemInstallation orderCCI version
Cannot use (except
CLI)
EnableHitachiCCICCI 01-08-03/00 or
higher
EX_ERPERM
1
HP XP
EnableHitachiInstall CCI after installing
RAID Manager XP
EnableHP XP
EnableEnableHP XPRAID Manager XPRAID Manager XP
01.08.00 or higher
(provided by XP)
EX_ERPERM
2
EX_ERPERM
1
Hitachi
EnableEnableHP XPInstall RAID Manager XP
after installing CCI
EX_ERPERM
2
EnableHitachi
Notes:
1. The following common API/CLI commands are rejected with EX_ERPERM by connectivity of CCI with RAID storage
system:
horctakeover
paircurchk
paircreate
pairsplit
pairresync