HP StorageWorks RAID Manager XP user guide (T1610-96005, March 2006)
200 HP StorageWorks Disk Array XP RAID Manager: User’s Guide
PFUS Since the PFUS state is referring to a Suspend state
with the Side File Full, the PFUS state is displayed as
PSUS by all commands except
pairvolchk and the –fc
option of the
pairdisplay command.
SVOL_PSUS Displayed as SSUS by the pairdisplay command.
Error Codes The table lists specific error codes for the pairvolchk command.
Examples
CA Async:
# pairvolchk -g oradb
pairvolchk:Volstat is P-VOL.[status=PAIR fence=ASYNC CTGID=2 MINAP=2
CA Sync:
# pairvolchk -g oradb
pairvolchk : Volstat is P-VOL.[status = PAIR fence = DATA MINAP = 2 LDEV =BLOCKED]
“MINAP” shows the minimum active paths to a specified group on the
P-VOL. If the array firmware does not support tracking the number of
active paths, then "MINAP" will not be displayed (as below).
“LDEV = BLOCKED indicates failure to link to an E-LUN by CA
BC:
# pairvolchk -g oradb
pairvolchk : Volstat is P-VOL.[status = PAIR ]
BC with CT Group:
# pairvolchk -g oradb
pairvolchk : Volstat is P-VOL.[status = PAIR CTGID = 1 ]
Category Error Code Error Message Value
Volume status
unrecoverable
EX_ENQVOL Unmatched volume status within the group 236
EX_EVOLCE Pair volume combination error 235