HP StorageWorks RAID Manager XP user guide (T1610-96005, March 2006)
180 HP StorageWorks Disk Array XP RAID Manager: User’s Guide
This option is effective without specification of the
–g group option.
If the specified LDEV is listed in multiple device
groups, this applies to the first one encountered.
seq # LDEV # can be specified in hexadecimal (by the
addition of 0
x) or decimal format.
–E (BC only) Issued to forcibly suspend a paired volume
(for example, when a failure occurs). It is not normally
used.
–FCA [MU#] Used to forcibly specify a cascading CA volume in a
combination CA and BC environment. If the
–l option
is specified, this option splits a cascading CA volume
on a local host (near site). If no
–l option is specified,
then this option splits a cascading CA volume on a
remote host (far site).
The target CA volume must be a P-VOL, or the
–R[S][B] option can be specified on the S-VOL.
The MU# specifies the cascading mirror descriptor for
CA-Journal.
–FBC [MU#] Used to forcibly specify a cascading BC volume in a
combination BC and CA environment. If the
–l option
is specified, this option splits a cascading BC volume
on a local host (near site). If no
–l option is specified,
then this option splits a cascading BC volume on a
remote host (far site).
The target BC volume must be a P-VOL, and the
–E option cannot be specified.
-fq <mode> (BC only) Specifies whether or not -split is performed
in QUICK mode.
The paircreate -split will be performed as a Quick Split
regardless of the
$HORCC_SPLT environment
variable setting and/or the Mode 122 via SVP setting.