150 HP StorageWorks Disk Array XP RAID Manager: User’s Guide
matches the specified raw_device. If a volume is found,
the command is executed on the paired volume (
–d) or
group (
–dg). If the volume is contained in two groups,
this command executes for the first volume
encountered only. If
MU# is not specified, it defaults to
0.
–d[g] seq# LDEV# [ MU# ]
Searches the RM instance configuration file (local
instance) for a volume that matches the specified
sequence number (
seq#) and LDEV. If a volume is
found, a command is executed on the paired logical
volume (
–d) or group (–dg). If the volume is contained
in two groups, this command executes for the first
volume encountered only. If
MU# is not specified, it
defaults to 0.
–f[x|c|d|m|e] –fx displays the LDEV number in hexadecimal.
–fc displays the copy operation rate and a completion
percentage. Detects and displays the status (PFUL,
PFUS) and confirms
SSWS state as an indication of
SVOL_SSUS-takeover. This option is also used to
display the copy operation progress, the Side File
percentage or the BITMAP percentage for
asynchronous pair volumes.
–fd displays the relationship between the Device_File
and the paired volumes, based on the group (as defined
in the local instance configuration definition file). If
Device_File column shows
unknown to either the local
or the remote host (instance), then it shows a volume
that is not recognized on the current host, and pair
operations are rejected (except the local option
–l in
protection mode).
–fm displays the Bitmap mode.
-fe displays the serial number and LDEV number of the
external LUNs mapped to the LDEV and additional