HP StorageWorks RAID Manager XP user guide (T1610-96005, March 2006)
139
–g[s] group Specifies the group to be paired; the group name is
specified in the
HORCM_DEV section of the RM
instance configuration file.
[s] is used to specify the cascading SVOL group name
(defined in the configuration definition file).
The following options can be specified for the
cascading SVOL:
-d[g]s <raw_device> [MU#]
-d[g]s <seq#> <LDEV#> [MU#]
The command executes for the entire group unless the
–ds pair_vol argument is specified.
–d[s] pair_vol Specifies a paired volume name written in the
configuration definition file. The command executes
only for the specified paired volume.
–d[g][s] raw_device [ MU# ]
(HP-UX, Linux, Solaris, MPE/iX, AIX, and
Windows
NT/2000/2003 only) Searches the RM
configuration file (local instance) for a volume that
matches the specified raw device. If a volume is found,
the command is executed on the paired volume (
–d) or
group (
–dg).
This option is effective without specifying the –g
<group>
option.
If the specified raw_device is listed in multiple device
groups, this applies to the first one encountered.
–d[g][s] seq# LDEV# [ MU# ]
Searches the RM instance configuration file (local
instance) for a volume that matches the specified
sequence # and LDEV. If a volume is found, the
command is executed on the paired logical volume (
–d)
or group (
–dg).