HP P9000 Remote Web Console Messages (AV400-96401, October 2011)
Table 33 Error codes (part code 3005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WAdd some Pool-VOL, or decrease the
snapshot data by restoring or deleting
the Snapshot pairs.
The operation cannot be done, because
the usage of the specified Pool is 100%
(full).
584703005
WInstall additional shared memory for the
V-VOL management area.
The shared memory for the V-VOL
management area is insufficient.
584713005
WWhen the pool information cannot be
acquired, do the following:
Acquisition of the pool information has
failed.
Pool information cannot be acquired
when:
584723005
• Check the installation status of the
V-VOL management area, when the
V-VOL management area is not
initialized.
• V-VOL management area is not
initialized.
• Check the installation status of the
V-VOL management area, when the
• V-VOL management area is not
installed.
V-VOL management area is not
installed.
WCheck the error message of the logical
volume(s) in the Pool.
An error occurred when setting the
Pool.
584733005
ECheck the amount of free space in Pool
management block in the Pool window.
The capacity of shared memory is
insufficient or an error occurred during
SVP processing.
584743005
Install additional shared memory if the
free space is insufficient.
Please contact HP Technical Support if
the capacity of shared memory is not
insufficient.
WInstall the PCB for fiber port, and retry
the operation.
The PCB for fibre port is not installed.584753005
EIf this problem persists, please contact
HP Technical Support.
A communication time-out error
occurred in the disk subsystem.
584913005
WDelete the Snapshot pair(s), then retry
the operation.
V-VOL management area is being used.585703005
WCheck the Pool-VOL setting.The specified operation cannot be
executed because the Pool-VOL is not
mounted.
585713005
WWait, then retry the operation. If an error
occurred while operating the pool,
An error occurred while communicating
with the storage system.
585723005
refresh the configuration by clicking
[Refresh All] on the [File] menu, then retry
the operation.
ECheck if the DKCMAIN and the SVP
microcode versions are mismatched.
This function is not supported.585733005
EIf this problem persists, please contact
HP Technical Support.
An error occurred while connecting to
the subsystem.
585743005
EIf this problem persists, please contact
HP Technical Support.
An error occurred while connecting to
the subsystem.
585753005
EIf this problem persists, please contact
HP Technical Support.
A communication time-out error
occurred in the disk subsystem.
585763005
WResynchronize the pair or release the
pair definition, then retry the operation.
The specified operation cannot be
performed, because the Snapshot pair
586233005
using the pool volumes to be
90 Message (part code group 3nnn)