HP P9000 Remote Web Console Messages (AV400-96401, October 2011)
Table 59 Error codes (part code 6610) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
Continuous Access Journal, then start the
Continuous Access Journal Z window or
the Continuous Access Journal window.
WReduce the number of journal volumes
to be registered, or increase the number
of journal volumes to be deleted.
The number of journal volumes in some
journals exceeds the maximum.
Adjust the number of journal volumes.
590436610
WUse the sort function to identify volumes
with the same LDKC number, the same
CU number and the same LDEV number.
The same volume is stored more than
once in the Preview list.
Please use the sort function to identify
volumes with the same LDKC number,
591006610
the same CU number and the same LDEV
number.
WCreate a volume that can be used as a
journal volume. To do this, add a volume
or use some other way.
There is no volume that can be registered
or deleted.
591036610
WSpecify another parity group.The specified parity group does not
contain volumes that can be registered
or deleted as journal volumes.
591046610
WCheck the CLPR number for the specified
data volume, and specify only one CLPR
number.
There are two or more CLPR numbers for
the specified data volume. In this
operation, please specify only one CLPR
number.
591116610
WSpecify only the volume that has the
same CLPR number as the CLPR number
of the volume in the Preview list.
The CLPR number of the specified data
volume is different from the CLPR number
of the data volume in the Preview list. In
591126610
this operation, please specify only one
CLPR number.
WCheck the CLPR number of the specified
volume and the CLPR numbers of volumes
Multiple CLPR numbers are existing in
the specified volume, or you tried to
591136610
if it is already existed. Specify a volumeregister a volume different from the CLPR
so that there is only one CLPR number in
the journal.
number of an existing volume. In one
journal, more than one CLPR numbers
cannot be existed.
WCheck the amount of the Preview data.
If the amount of the Preview data is too
The number of Preview data may have
exceeded the limit, or too large number
of data is selected.
591156610
large, clear the Preview data by clicking
[Apply], and then retry the operation.
If the amount of Preview data is small or
there is no Preview data, too much data
is selected. Reduce the number of data,
and retry the operation.
WCheck the microcode version of the
DKCMAIN, then contact HP Technical
Support.
The specified function is not supported
by the current microcode version.
591166610
WCheck the microcode version of
DKCMAIN. To use other emulation types,
The current microcode version of
DKCMAIN does not support Add Pair
591506610
please contact HP Technical Support to(Paircreate) operations, Resume Pair
update the microcode version of
DKCMAIN.
operations, and Change Pair Option
operations using the emulation type of
the specified volume.
238 Message (part code group 6nnn)