HP P9000 Remote Web Console Messages (AV400-96401, October 2011)

Table 56 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck if the specified journal belongs to
an extended consistency group (EXCTG).
The timer type cannot be changed,
because the specified journal belongs to
an extended consistency group (EXCTG).
586096505
WRefresh the window, then retry the
operation. If this problem persists, please
contact HP Technical Support.
The parameter specified in the extended
consistency group (EXCTG) operation is
invalid.
586106505
WRetry the operation after the microcode
exchange completes.
The specified operation failed because
the microcode exchange was in progress
586116505
on the subsystem in the extended
consistency group (EXCTG).
WWait a while, then retry the operation.The previously executed update
processing of the extended consistency
586126505
group (EXCTG) has not completed.
Please wait for a while, and then retry
the operation.
WCheck whether the specified CU number
and the LDEV number indicate a
command device.
The command device is specified
incorrectly.
586136505
WVerify the status of the specified journal.The specified Journal cannot be added
to the extended consistency group
586146505
(EXCTG), because the journal is not
registered, or the journal is in the Initial
state.
WCheck the mirror ID of the specified
journal.
Journals cannot be added to the
extended consistency group (EXCTG),
586156505
because the specified mirror ID is not
registered in the specified journal.
WCheck the state of the journal in the
storage system where the specified
The specified journal cannot be added
to extended consistency group (EXCTG).
586166505
journal belongs to, or the installation
status of the program product.
WCheck the attributes of the specified
extended consistency group (EXCTG)
and the journal.
Journals cannot be added to the
extended consistency group (EXCTG),
because the attributes of the EXCTG and
the journal are different.
586176505
WCheck the timer type of the specified
journal.
Journals cannot be added to the
extended consistency group (EXCTG),
586186505
because the timer type of the specified
journal is not "System."
WWait for a while, refresh the window,
then retry the operation.
The status of the extended consistency
group (EXCTG) is changing.
586206505
WCheck the attribute of the specified
journal.
Journals cannot be added to the
extended consistency group (EXCTG),
586216505
because the attribute of the specified
journal is invalid.
WCheck if the specified command device
exists in the device of specified serial
number.
Journals cannot be added to the
extended consistency group (EXCTG),
because the combination of the serial
586246505
number and the command device is
invalid.
Part code 6505 211