HP P9000 Remote Web Console Messages (AV400-96401, October 2011)
Table 56 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
• A Thin Provisioning volume used as
a P-VOL of Business Copy.
• A Thin Provisioning volume and a
source volume of Auto LUN.
• A Thin Provisioning volume used as
a P-VOL of Snapshot.
WCheck if the specified primary data
volume is used by any of the following
program products:
The specified primary data volume is
used by another program product.
583546505
• Business Copy/Snapshot
• Continuous Access Synchronous
• External Storage Access Manager
• Auto LUN
WCheck whether the specified secondary
data volume is used by the following
program products.
The specified secondary data volume is
used by one of the following program
products.
583556505
• Business Copy/Snapshot• Business Copy/Snapshot
• •Continuous Access Synchronous Continuous Access Synchronous
•• External Storage Access ManagerExternal Storage Access Manager
• •Auto LUN Auto LUN
WIf the problem persists despite retrying,
please contact HP Technical Support.
The disk subsystem is in internal process.
Please retry the operation.
584516505
WFrom the Compatible FlashCopy
window, check the status of the specified
primary data volume.
The operation failed because the
specified primary data volume was one
of the following:
584566505
• It was a T-VOL of Compatible
FlashCopy.
• It was being used by Compatible
FlashCopy SE.
• It was a TSE-VOL.
WSpecify a mirror ID other than 0, then
retry the operation.
Continuous Access Synchronous, External
Storage Access Manager, or Continuous
584576505
Access Synchronous Z is using the
specified primary data volume. Specify
a mirror ID other than 0 if you use this
volume to create a pair.
WSpecify the same mirror ID as the
registered mirror ID, then retry the
operation.
A different mirror ID has already been
registered in the specified master journal.
Specify the same mirror ID, because only
one mirror ID can be registered in one
journal.
584586505
WFrom the Compatible FlashCopy
window, check the status of the specified
secondary data volume.
The operation failed because the
specified secondary data volume was
one of the following:
584596505
• It was being used by Compatible
FlashCopy.
• It was being used by Compatible
FlashCopy SE.
• It was a TSE-VOL.
206 Message (part code group 6nnn)