HP P9000 Remote Web Console Messages (AV400-96401, October 2011)

Table 56 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the status of the specified
secondary data volume.
A Concurrent Copy operation is in
progress on the specified secondary data
volume.
582726505
WUse Volume Security for Mainframe to
check the status of the specified
secondary data volume.
Either of the following settings is set to
the specified secondary data volume by
the Volume Security for Mainframe
function.
The volume belongs to the access
group or the pool group.
The setting does not allow the volume
to be used as a secondary data
volume.
582736505
WCheck the specified restore journal.The specified restore journal is not
registered.
582756505
WCheck the status of the specified
secondary data volume.
The specified secondary data volumes
cannot be paired with another volume,
582766505
because the secondary data volume is
used as a journal volume.
WCheck the data volumes in the specified
secondary journal.
The specified secondary data volume is
not registered in the specified journal.
582776505
WCheck the status of the specified restore
journal.
The specified restore journal is not
registered.
582786505
WCheck the emulation type of the specified
secondary data volume or the restore
journal volume.
The emulation type of the specified
secondary data volume and the restore
journal volume is incorrect due to one of
the following reasons:
582796505
The emulation type is not supported.
The combination of emulation types
within the journal is incorrect.
The combination of emulation types
between the journal volumes of the
master and restore journals is
incorrect.
The emulation types of the primary
and secondary data volumes are not
the same.
WCheck the status of the specified
secondary data volume.
The specified secondary data group is
already registered.
582806505
WCheck the number of pairs in the
specified restore journal.
No more pairs can be registered in the
specified restore journal.
582816505
WIdentify the journal where the specified
secondary data volume is registered.
The specified secondary data volume is
already registered in another journal.
582826505
WIdentify the journal where the specified
secondary data volume is registered.
The specified secondary data volume
cannot be deleted, because the volume
is already registered in another journal.
582836505
EPlease contact HP Technical Support.An internal error occurred.582846505
WCheck the number of pairs.No more pairs can be registered
because the number of pairs will exceed
the maximum.
582856505
Part code 6505 201