HP P9000 Remote Web Console Messages (AV400-96401, October 2011)

Table 53 Error codes (part code 6005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
EIf the extended shared
memory (SM #2) is not
No more space is left in RCU for
differential management.
89066005
installed in RCU, install the
shared memory to RCU
according to the installation
instruction of the extended
shared memory for remote
copy ("Shared Memory Size
Configuration" dialog box),
then create a pair.
If SM #2 is installed in RCU,
you cannot create any more
pairs because the number of
pairs has already reached
the maximum that can be
created by the system.
EInstall the extended shared
memory to RCU according
The extended SM is not equipped in
RCU.
89076005
to the installation instruction
of the extended shared
memory for remote copy
("Shared Memory Size
Configuration" dialog box).
WSpecify a correct value.Invalid parameter.89086005
EPlease contact HP Technical
Support.
A Port exchange error occurred.89096005
EPlease contact HP Technical
Support.
A Port exchange error occurred.89106005
WDelete the LUs defined on
the specified port, then retry
the operation.
Logical paths exist on the port.89116005
WDelete the LUs defined on
the specified port, then retry
the operation.
Logical paths exist on the port.89126005
WRefresh the window, then
retry the operation.
Invalid port type.89136005
If the same problem persists
despite retrying, please
contact HP Technical
Support.
WCheck the configuration of
the storage system.
Multi platform feature is already
installed in the storage system.
89146005
WRefresh the window, then
retry the operation.
The port type exchange operation is
rejected because the host(s) is(are)
processing the port type exchange.
89156005
If the same problem persists
despite retrying, please
contact HP Technical
Support.
WCheck the status of the
specified M-VOL.
The specified M-VOL must not be in an
intervention-required condition, in a
89216005
protection condition, in an unusable
condition, the Business Copy/Business
Part code 6005 167