HP P9000 Remote Web Console Messages (AV400-96401, October 2011)
Table 53 Error codes (part code 6005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
memory, then retry the
operation.
WConfirm the controller type
of the RCU.
Continuous Access Synchronous or
External Storage Access Manager is
87796005
not supported under the RCU controller
type.
WInstall the Continuous Access
Synchronous Z in the MCU
and the RCU.
Continuous Access Synchronous Z
function is not installed in the specified
controller.
87806005
WInstall the Continuous Access
Synchronous Z in the MCU
and the RCU.
Continuous Access Synchronous Z
function is not installed in the specified
controller.
87816005
WCheck the volume again.The M-VOL is defined as the expansion
volume.
87856005
WCheck the volume again.The R-VOL is defined as the expansion
volume.
87866005
WCheck the Port, GID and
LUN settings of the RCU.
The specified expanded volume in the
RCU is not defined.
87886005
WVerify the configuration of
both the M-VOL and the
R-VOL.
Combination of the M-VOL and R-VOL
configuration is not valid.
87896005
WConfirm the status of the
specified expansion volume
The specified expansion volume
(Port/GID/LUN) of the RCU is not
usable.
87906005
and microcode version of
the RCU.
WVary the concerned path
offline from the other host,
then retry the operation.
The specified M-VOL is still online from
another HOST.
87916005
WInstall the Volume Retention
in the MCU and the RCU,
then retry the operation.
The operation failed because the
Volume Retention function was not
installed in the specified RCU.
87926005
Install the Mainframe Array
Management in the MCU
Install Volume Retention, and retry the
operation.
and the RCU, then retry the
operation.
The operation failed because the
Mainframe Array Management function
was not installed in the specified RCU.
WInstall Continuous Access
Synchronous in the MCU
The Continuous Access Synchronous
function is not installed in the specified
controller(s).
87936005
and the RCU, then retry the
operation.
WInstall Continuous Access
Synchronous in the MCU
The Continuous Access Synchronous
function is not installed in the specified
controller(s).
87946005
and the RCU, then retry the
operation.
WCheck the status of the
specified M-VOL from the
host or the SVP.
The operation failed because the
specified M-VOL applied to any of the
following:
87956005
• A T-VOL of Business Copy Z which
is not in the Split pair (PSUS) status.
• An S-VOL of Business Copy which
is not in the Split pair (PSUS) status.
Part code 6005 159