HP P9000 Remote Web Console Messages (AV400-96401, October 2011)

Table 53 Error codes (part code 6005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WThe specified number of
paths is less than the
Specified number of paths is less than
the minimum specified on RCU Option
screen.
87246005
minimum number of paths
specified on the RCU Option
window.
WThe version of the microcode
on the 9900 storage system
Current microcode version does not
support the specified operation.
87256005
does not support the
specified function or
operation. Please contact HP
Technical Support.
WAdd the normal path(s), then
set the minimum number of
paths.
The number of minimum paths exceeds
the number of normal paths.
87276005
WPlease take either of the
following actions:
The number of minimum paths exceeds
the number of normal paths.
87286005
Add normal paths, then
delete the paths.
Decrease the number of
minimum paths, then delete
the paths.
EPlease contact HP Technical
Support.
An internal error occurred.87296005
WIf you are adding RCUs,
specify the same logical
address.
Invalid Logical Addresses are specified.87306005
If you are editing paths,
specify the same logical
address as the existing
paths. (See the Edit Path
dialog box.)
WThe logical addresses of all
existing paths are not the
The existing logical addresses are not
equal.
87316005
same. Delete the RCU, then
re-add it, using the same
logical address as other
existing paths.
WThe maximum number of
SSIDs (four) has been
Too many SSIDs (only Four SSIDs are
allowed).
87326005
entered. Verify that the SSIDs
are valid, delete one or
more, then retry the
operation.
WInstall the program product
key in the MCU.
The Fibre-Remote Copy function is not
installed in the specified MCU.
87336005
WInstall the program product
key in the RCU.
The Fibre-Remote Copy function is not
installed in the specified RCU.
87346005
WCheck the serial number,
SSID and link address of the
Invalid RCU serial number, SSID, Link
Address or Controller ID.
87356005
RCU, and set the correct
value. Then retry the
operation. If the same error
154 Message (part code group 6nnn)