HP P9000 RAID Manager User Guide
Table 76 SSB codes that are returned by raidcom modify rcu command
raidcom modify rcu
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
CU# of RCU exceed the effective value.30012E00ExecutingCMDRJE
The value of least path number is invalid.30022E00ExecutingCMDRJE
The value of RIO MIH time is invalid.30032E00ExecutingCMDRJE
The value of Round-trip response time is invalid.30042E00ExecutingCMDRJE
Invalid product ID or path registration ID.30052E00ExecutingCMDRJE
Incident that is created by CU is not in the one of following:30072E00ExecutingCMDRJE
- Incident that is sent to MCU host and RCU.
- Incident that is sent to RCU.
Command cannot be executed because the parameter of
specified RCU is invalid.
30082E00AsynchronousGet Command Status
Command cannot be executed because all the CU numbers in
the RCU is not unified at the path that is specified creation or
deletion.
30092E00AsynchronousGet Command Status
CU number is out of effective range.71002E00ExecutingCMDRJE
The operation cannot be done because the microcode is being
changed.
80042E11ExecutingCMDRJE
The attribute of the RCU cannot be changed because the
specified RCU is not registered.
30012E20ExecutingCMDRJE
The specified CU number is not defined, or an LDEV is not
defined under the CU number.
71012E21AsynchronousGet Command Status
The operation cannot be done because the number of paths
become less than the least path number.
31012E23ExecutingCMDRJE
Command cannot be executed because the RCU identification
code of a path is invalid.
30012E31AsynchronousGet Command Status
An internal error occurred.00EF2ED6ExecutingCMDRJE
Call HP Technical Support.
The value of SSID for the remote DKCstorage system is invalid.33002ED6ExecutingCMDRJE
Table 77 SSB codes that are returned by raidcom delete rcu_path command
raidcom delete rcu_path
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
The CU# of RCU exceeds the effective value.30012E00ExecutingCMDRJE
The product ID or the path registration ID is invalid.30052E00ExecutingCMDRJE
Command cannot be executed because the parameter of
specified RCU is invalid.
30082E00AsynchronousGet Command Status
The specified port # on the side of RCU is invalid.32002E00ExecutingCMDRJE
CU number is out of effective range.71002E00Executing/
Asynchronous
CMDRJE
Get Command Status
230 Troubleshooting