HP P9000 RAID Manager User Guide
Table 53 SSB codes that are returned by raidcom add journal command (continued)
raidcom add journal
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
The specified LDEV cannot be operated because it is an external
volume mapped for online data migration.
00742E30AsynchronousGet Command Status
The command cannot be accepted. After a while, execute the
same command.
08E62EE4ExecutingCMDRJE
An internal error occurred.50EE2EE4AsynchronousGet Command Status
Call HP Technical Support.
An internal error occurred.FEEC2EE4ExecutingCMDRJE
Call HP Technical Support.AsynchronousGet Command Status
Table 54 SSB codes that are returned by raidcom modify journal command
raidcom modify journal
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
The specified volume capacity is too small.00232E00ExecutingCMDRJE
The specified path block watch time exceeds the range.500B2E00ExecutingCMDRJE
The specified MP Blade ID is invalid.83012E00ExecutingCMDRJE
The specified volume is not installed or cannot be used.00112E10ExecutingCMDRJE
The specified operation failed because the journal or mirror is
not in the operable status.
50002E10ExecutingCMDRJE
The specified operation failed because the mirror of journal is
not in the operable status.
50062E10ExecutingCMDRJE
The specified MP Blade is blocked.83002E10ExecutingCMDRJE
The operation cannot be done because it is in the state of
start-up.
800B2E11ExecutingCMDRJE
The specified journal ID is not registered.50002E20ExecutingCMDRJE
The operation failed because the specified journal is not
registered.
50002E21ExecutingCMDRJE
The journal volume cannot be added, or the journal cannot be
added to the extended CT group due to insufficient capacity of
the shared memory (SM).
81042E21ExecutingCMDRJE
The specified volume cannot be used as a journal volume
because it is an external volume that can execute the I/O
suppression mode.
00622E30AsynchronousGet Command Status
The timer type cannot be changed because the specified journal
belongs to the extended CT group.
50012E30ExecutingCMDRJE
The parameter of inflow control cannot be changed because
the specified journal is not a primary journal.
50032E30ExecutingCMDRJE
The cache mode option or the data overflow monitoring time
cannot be changed because the specified journal is used by
both the primary and the secondary journals.
50052E30ExecutingCMDRJE
An internal error occurred.50EE2EE4ExecutingCMDRJE
212 Troubleshooting