HP P9000 RAID Manager Reference Guide (T1610-96037, October 2011)

Example 7: raidvchkdsp command example with -v aou option
[Display example]
# raidvchkdsp -v aou -g AOU
Group PairVol Port# TID LU Seq# LDEV# Used(MB) LU_CAP(MB) U(%) T(%) PID
AOU AOU_001 CL2-D 2 7 62500 167 20050 1100000 10 70 1
AOU AOU_002 CL2-D 2 10 62500 170 110000 1100000 10 70 1
Output of the raidvchkdsp command with the -v aou option:
Used(MB): Displays the usage size of the allocated block on this LUN. Range: 0 Used (MB) <
LU_CAP(MB) + 42 MB
LU_CAP(MB): Displays the LUN capacity responded to the “Readcapacity” command as SCSI
interface.
LU_CAP(BLK): Displays the LUN capacity (in block/512 bytes) responded to the “Readcapacity”
command as SCSI interface.
U(%): Displays the usage rate of the allocated block on the Thin Provisioning pool containing this
LU.
T(%): Displays the threshold rate being set to the Thin Provisioning pool as high-water mark.
PID: Displays the Thin Provisioning pool ID assigned to this Thin Provisioning volume.
raidvchkscan
The raidvchkscan command displays the fibre port of the storage system (XP1024/XP128 Disk
Array and later), target ID, LDEV mapped for LUN#, and the parameters for validation checking,
regardless of the configuration definition file.
Note: This command is rejected with EX_ERPERM by connectivity checking between RAID Manager
and the RAID storage system.
Syntax
raidvchkscan { -h | -q | -z | -I[H][M][instance#] or I[CA][BC][instance#]
| -p <port> [hgrp] | -pd[g] <raw_device> | -s <seq#>
| -t <target> | -l <lun> | [ -f[x] ] | -v <op> }
Options and parameters
DescriptionOption
Displays Help/Usage and version information.-h
Terminates the interactive mode and exits the command.-q
Makes the raidvchkscan command enter the interactive mode. The -zx option guards performing of
the HORCM in the interactive mode. When this option detects a HORCM shutdown, interactive mode
terminates.
-z or -zx
OpenVMS cannot use the -zx option.
Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy],
and used when specifying the RAID Manager instance number.
-I[H][M]
[instance#]
or
-I[CA][BC]
[instance#]
Specifies a group name written in the configuration definition file.-g <group>
Specifies the port ID of the port to be scanned. Valid ports are CL1-A to CL1-R and CL2-A to CL2-R
(excluding CL1-I, CL1-O, CL2-I, CL2-O). In addition:
-p <port> [hgrp]
For XP24000/XP20000 Disk Array: CL3-a to CL3-r, or CLG-a to CLG-r for the expanded port For
XP12000 Disk Array: CL3-a to CL3-r, or CLG-a to CLG-r for the expanded port.
For XP10000 Disk Array: CL3-a to CL3-h, or CL8-a to CL8-h for the expanded port.
78 Replication commands