HP P9000 RAID Manager Reference Guide (T1610-96037, October 2011)
Cache(MB): Shows the logical cache capacity (in MB) of the storage system connected to the local
or remote host. The -l option specifies local host, and -r specifies remote host.
Example 2
# raidqry -g
GNo Group RAID_type IV/H IV/M MUN/H MUN/M
1 ora HTC_RAID 12 9 4 64
2 orb XP_RAID 12 9 4 64
3 orc HTC_DF 8 6 1 1
GNo: The order of the group name (dev_group) described in the configuration definition file.
Group: The group name (dev_group) described in the configuration definition file.
RAID_type: The type of RAID configured in the group.
IV/H: The interface version for HORC that made the consistence in a group, this is used for the
maintenance.
IV/M: The interface version for HOMRCF that made the consistence in a group, this is used for
the maintenance.
MUN/H: The number of maximum MUs for HORC/Cnt Ac-J that made the consistence in a group.
MUN/M: The number of maximum MUs for HOMRCF that made the consistence in a group.
raidvchkset
The raidvchkset command sets the parameters for validation checking of the specified volumes,
and can also be used to turn off all validation checking without specifying [type]. Unit of checking
for the validation is based on the group of RAID Manager configuration definition file.
This command is controlled as protection facility. This command is rejected with EX_ERPERM by
connectivity checking between RAID Manager and the RAID storage system.
Syntax
raidvchkset { -h | -q | -z | -I[H][M][instance#] or I[CA][BC][instance#]
| -g <group> | -d <pair Vol> | -d[g] <raw_device> [MU#]
| -d[g] <seq#> <LDEV#> [MU#] | -nomsg | -vt [type]
| -vs < bsize> [slba] [elba] | -vg [type]… [rtime] | -vext <size> }
Options and parameters
DescriptionOption
Displays Help/Usage and version information.-h
Terminates the interactive mode and exits the command.-q
Makes the raidvchkset command enter the interactive mode. The -zx option guards performing of
the HORCM in the interactive mode. When this option detects a HORCM shut down, interactive
mode terminates.
-z or -zx
OpenVMS cannot use the -zx option.
Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy],
and used when specifying the RAID Manager instance number.
-I[H][M]
[instance#]
or
-I[CA][BC]
[instance#]
Specifies a group name written in the configuration definition file.-g <group>
Specifies paired logical volume name defined in the configuration definition file. When this option
is specified, the command is executed for the specified paired logical volume.
-d <pair Vol>
70 Replication commands