HP P9000 RAID Manager Reference Guide (T1610-96037, October 2011)

status is logged in the RAID Manager command log ($HORCC_LOG), even if the user script has
no error handling.
Table 18 Error codes for horctakeover
ValueRecommended actionError messageError codeCategory
236Confirm status using pairdisplay
command. Make sure all volumes in the
Unmatched volume status
within the group
EX_ENQVOLVolume status
group have the same fence level and
volume attributes.
229Confirm pair status using pairdisplay.Inconsistent status in groupEX_INCSTG
235Confirm pair status using pairdisplay,
and change combination of volumes.
Pair Volume combination
error
EX_EVOLCE
225Check volume list to see if an operation
was directed to the wrong S-VOL.
S-VOL currency errorEX_VOLCUR
224Confirm pair status of the local volume.Local Volume currency errorEX_VOLCUE
223Confirm pair status of remote and local
volumes using pairdisplay command.
Local and Remote Volume
currency error
EX_VOLCREUnrecoverable
233Increase timeout value using -t option.Timeout waiting for specified
status
EX_EWSTOTTimer Recoverable
Examples
For examples of the hortakeover command, see Horctakeover command functions in the User and
Reference Guide.
raidscan
The raidscan command displays configuration and status information for the specified
port/TID(s)/device(s). The information is acquired directly from the storage system (not the
configuration definition file).
Syntax
raidscan { -h | -q | -z | -I[H][M][instance#] or I[CA][BC][instance#]
| -p <port> [hgrp]|-pd[g] <raw_device> | -s <Seq#> | -t <targ>
| -l <lun> | [ -f[xfgde] ] | -CLI | -find[g] [op] [MU#]
| -pi <strings> | -m <MU#> }
Options and parameters
DescriptionOption
Displays Help/Usage and version information.-h
Terminates the interactive mode and exits the command.-q
Makes the raidscan command enter the interactive mode. The -zx option guards performing of the
HORCM in the interactive mode. When this option detects a HORCM shutdown, interactive mode
terminates.
-z or -zx
OpenVMS cannot use the -zx option.
Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy],
and used when specifying the RAID Manager instance number.
-I[H][M]
[instance#]
or
-I[CA][BC]
[instance#]
raidscan 61