HP P9000 RAID Manager Reference Guide (T1610-96037, October 2011)

Table 15 Truth table for pairvolchk group status display (continued)
Group statusPAIRPFULPSUSPFUSPDUBPSUECOPY/RCPYOption
PFULxTRUEfalsefalsefalsefalsefalse
PAIRTRUEfalsefalsefalsefalsefalsefalse
COPY/RCPYxxxxxxTRUE-ss
PSUExxxxxTRUEfalse
PDUBxxxxTRUEfalsefalse
PFULxTRUExxfalsefalsefalse
PAIRTRUEfalsexxfalsefalsefalse
PFUSfalsefalsefalseTRUEfalsefalsefalse
PSUSfalsefalseTRUEfalsefalsefalsefalse
COPY/RCPYxxxxxxTRUE
NOTE:
The PFUL state appears as PAIR by all commands (except the -fc option of the pairdisplay
command), since PFUL indicates PAIR state with sidefile at the HWM.
The PFUS state appears as PSUS by all commands (except the -fc option of the pairdisplay
command), since PFUS indicates SUSPENDED state due to sidefile full.
The S-VOL_PSUS state appears as SSUS by the pairdisplay command and other commands.
This option can be used under condition when pairvolchk -s has “USE_OLD_VCHK” variable.
pairdisplay
The pairdisplay command displays the pair status allowing you to verify completion of pair
operations (For example, paircreate, pairresync). The pairdisplay command is also used to confirm
the configuration of the pair connection path (the physical link of paired volumes and servers). The
pairdisplay command can be used for a paired volume or a group of paired volumes.
Syntax
pairdisplay{ -h | -q | -z | -I[H][M][instance#] or I[CA][BC][instance#]
| -g <group> | -d <pair Vol> | -d[g] <raw_device> [MU#]
| -FHORC [MU#]| -FMRCF [MU#] | -d[g] <seq#> <LDEV#> [MU#]
| -c | -l | -f[xcdmew] | -CLI | -m <mode> | -v jnl[t]
| -v ctg | -v pid }
Options and parameters
DescriptionOption
Displays Help/Usage and version information.-h
Terminates the interactive mode and exits the pair volume check command.-q
Makes the pairdisplay command enter the interactive mode. The -zx option guards performing of
the HORCM in the interactive mode. When this option detects a HORCM shutdown, interactive mode
terminates.
-z or -zx
OpenVMS cannot use the -zx option
Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy],
and used when specifying the RAID Manager instance number.
-I[H][M]
[instance#]
or
50 Replication commands