HP P9000 RAID Manager Reference Guide (T1610-96037, October 2011)
Table 11 Pairevtwait Returned Values (continued)
ValueCondition
The status is PSUE.
Normal termination: 0. When monitoring groups, 0 = normal termination for all
pairs.
When the -nowait and/or nowaits
option is not specified:
Abnormal termination: Other than 0 to 127, see the execution logs for error details.
Error codes
Unrecoverable errors are fixed and not resolved, even after re-executing the command. If the
command failed, the detailed status is logged in the RAID Manager command log ($HORCC_LOG),
even if the user script has no error handling.
Table 12 Specific error codes for pairevtwait
ValueRecommended actionError messageError codeCategory
236Confirm status using the pairdisplay command.
Make sure all volumes in the group have the
same fence level and volume attributes.
Unmatched volume
status within the
group
EX_ENQVOLVolume status
229Confirm pair status using pairdisplay.Inconsistent status in
group
EX_INCSTG
222Confirm pair status using pairdisplay -l.Invalid volume statusEX_INVVOL
235Confirm pair status using pairdisplay, and
change combination of volumes.
Pair Volume
combination error
EX_EVOLCE
234Issue pairresync manually to the identified
failed paired volume to try to recover it. If the
trouble persists, call HP Technical Support.
Pair suspended at
WAIT state
EX_EWSUSEUnrecoverable
233Increase timeout value using -t option.Timeout waiting for
specified status
EX_EWSTOTTimer
232Confirm that RAID Manager (HORCM) on the
remote host is running.
Timeout waiting for
specified status on
the local host
EX_EWSLTORecoverable
Examples
Figure 18 Example of -FHORC option for Pairevtwait
pairevtwait 41