HP P9000 RAID Manager Reference Guide (T1610-96037, October 2011)
Abnormal termination: Other than 0, see the execution logs for error details.
Error codes
Unrecoverable errors are fixed and not resolved, even after re-executing the command. If the
command failed, the detailed status is logged in the RAID Manager command log ($HORCC_LOG),
even if the user script has no error handling.
The primary and secondary volumes must not be mounted on any UNIX system, because the
pairresync command renews data on both the primary and secondary volumes. This command
cannot execute copy rejection in case of error (For example, single error in cache memory) which
made the target volume is accompanied by maintenance work (HORC only).
Table 10 Specific error codes for pairresync
ValueRecommended actionError messageError codeCategory
236Confirm status using the pairdisplay command.
Make sure all volumes in the group have the
same fence level and volume attributes.
Unmatched volume
status within the
group
EX_ENQVOLVolume status
229Confirm pair status using pairdisplay.Inconsistent status in
group
EX_INCSTG
222Confirm pair status using pairdisplay -l.Invalid volume statusEX_INVVOL
228Confirm pair status using pairdisplay.Invalid pair statusEX_INVSTPUnrecoverable
Examples
Figure 13 Example of -FHORC option for pairresync
Figure 14 Example of -FMRCF option for pairresync
pairresync 37