HP P9000 RAID Manager Reference Guide (T1610-96037, October 2011)

ValueRecommended actionError messageError codeCategory
228Confirm pair status using pairdisplay.Invalid pair statusEX_INVSTP
212Confirm volume size or number of LUSE
volume using raidscan f, and make sure
volume sizes are identical.
Unmatched volume size
for pairing
EX_ENQSIZUnrecoverable
217Choose an existing CTGID (pairvolchk
displays CTGIDs). Use ‘-f async <CTGID>‘ or
Not enough CT groups
in the RAID
EX_ENOCTGResource
‘-m grp <CTGID>‘ option of paircreate to
force the pair into a pre-existing CTGID.
215Confirm whether all CT groups are already
used by Continuous Access
No CT groups left for
OPEN Vol use.
EX_ENXCTG
Synchronous/Continuous Access
Asynchronous or BC/SS.
206Could not retain the pool for executing a
command due to be exceeded the threshold
rate.
Not enough Pool in
RAID
EX_ENOPOLUnrecoverable
Delete unnecessary/earlier generations
paired volume, or re-synchronize
unnecessary/earlier generations split volume.
Examples
Example 1
The following figure shows an example of creating a cascading configuration with -g <group>
and -gs <group> option from the local node (takeover node).
Figure 4 Creating a cascading configuration from the local node
Example 2
The following figure shows an example for creating a suspended journal volume.
On DC1 side:
paircreate -g G1 -gs G2 -FHORC 2 -nocsus -f async <ctgid> -jp <id> -js <id>
On DC2 side:
paircreate -g G3 -vl -nocsus -f async <ctgid> -jp <id> -js <id>
On DC3 side:
paircreate -g G3 -vr -nocsus -f async <ctgid> -jp <id> -js <id>
Note: The journal ID for the shared Cnt Ac-J-S-VOL must be specified the same journal ID for S-VOL
currently. The CTGID for paircreate can be specified the same CT group for S-VOL currently.
26 Replication commands