HP P9000 RAID Manager Reference Guide (T1610-96037, October 2011)
Syntax
raidcom get port [-port <port>]
Options and parameters
DescriptionOption
Specifies a port number. If the port number is specified for the port which is enabled LUN
security, it displays LOGIN WWN.
[-port <port>]
For example:
CL1-A
Examples
Displaying port information.
In case of mainframe port (ESCON, FICON), "-" is displayed to the rows from SPD to SSW.
#raidcom get port
PORT TYPE ATTR SPD LPID FAB CONN SSW SL Serial# WWN PHY_PORT
CL1-A FIBRE TAR AUT EF N FCAL N 0 64568 50060e8006fc3800 -
CL1-B FIBRE TAR AUT EF N FCAL N 0 64568 50060e8006fc3801 -
CL1-C FICON TAR - - - - - 0 64568 50060e8006fc3802 -
CL1-D FICON TAR - - - - - 0 64568 50060e8006fc3803 -
CL2-A FIBRE TAR AUT D9 N FCAL N 0 64568 50060e8006fc3810 -
CL2-B FIBRE TAR AUT D3 N FCAL Y 0 64568 50060e8006fc3811 -
CL2-C FICON TAR - - - - - 0 64568 50060e8006fc3812 -
CL2-D FICON TAR - - - - - 0 64568 50060e8006fc3813 -
CL3-A FIBRE MCU AUT E8 N FCAL N 0 64568 50060e8006fc3820 -
CL3-B FIBRE TAR AUT E0 N FCAL Y 0 64568 50060e8006fc3821 -
Description on each column in output example
PORT
It displays the port numbers.
TYPE
This displays the following package type on a port.
FIBRE, SCSI, ISCSI, ENAS, ESCON, FICON
ATTR
This displays the following attribute setting on a port. One of the following items is displayed.
• TAR: Fibre Target port (Target port)
• MCU: MCU Initiator port (Initiator port)
• RCU: RCU Target port (RCU Target port)
• ELUN: External Initiator port (External port)
SPD
This displays the transfer rate setting on a port. One of the following values is displayed.
AUT(AUTO), 1G,2G,4G, 8G…
LPID
This displays the Loop ID(AL_PA) setting on a port.
FAB
This displays the fabric mode setting on a port as Y(YES) or N(NO).
CONN
This displays the following topology setting on a port.
164 Configuration setting commands