HP P9000 RAID Manager Reference Guide (T1610-96037, October 2011)

MP#
This displays MP Blade ID.
raidcom modify journal
Changes an option of Cnt Ac-J to be used at journal.
It sets a specified control parameter to the journal.
If the -mp_blade_id option is specified, the other option (-data_overflow_watch, -
path_blocked_watch, -cache_mode, -timer_type) cannot be specified.
“-timer_type” option must be specified to the journal on “M/F System.
This means that this option cannot be used for changing from “Open System to ”M/F System.
Syntax
Specify more than one option when specifying the data overflow watching time of journal data
area, path blocked watch or the timer type, specify more than one option.
raidcom modify journal -journal_id <journal ID#> {[-data_overflow_watch<time>]
[-cache_mode <y/n>][-timer_type <type>]}
When specifying the path blocked watch or the Mirror ID.
raidcom modify journal -journal_id <journal ID#> -path_blocked_watch <time>
[-mirror_id <mun#>]
When specifying the MP Blade ID.
raidcom modify journal -journal_id <journal ID#> -mp_blade_id <mp#>
Options and parameters
DescriptionOption
Specifies a journal number (0-255).-journal_id <journal ID#>
The data overflow watch timer (0-600) (seconds).-data_overflow_watch<time(sec)>
Specifies the watch time for the journal data area being full.
The watch for the path blockage (1-60) (minutes).-path_blocked_watch<time(min)>
Use Remote Web Console to set the value with more than 60 minutes.
If 0 is specified, the time of the watch for the path blockage does not
change, and the watch for the path blockage is invalid.
Specifies whether to use the cache mode.-cache_mode <y/n>
y: Cache mode enabled (E)
n: Cache mode disabled (D)
Specifies a timer type among system, local or None. For details, see the
Cnt Ac-J manual for the Timer Type option.
-timer_type <timer type>
For example:
-timer_type system
-timer_type system
Specifies an MP Blade ID (0-7).-mp_blade_id <mp#>
Changing MP Blade ID should be executed during off-peak hours of I/O
loading. Do not change the MP blade ID during initial copying of
Continuous Access Journal (on-peak hours of I/O loading).
To change the MP Blade ID again for the same journal, wait for more than
30 minutes after changing the MP Blade ID.
140 Configuration setting commands