Table 2 Command tools for RAID Manager
DescriptionSubcommand
Used to confirm the drive connection between the storage system and host system. The
inqraid command displays the relation between special file(s) on the host system and actual
physical drive of the RAID storage system.
inqraid
Used to make a configuration file from a special file (raw device file) provided via STDIN.mkconf
The following table describes the environment variable subcommands. If no environment variables
are set in the execution environment, the environment variable subcommands set or cancel an
environment variable within the RAID Manager command.
Table 3 Environment variable subcommands
DescriptionSubcommand
Displays the environment variable(s).env
Sets the specified environment variable(s).setenv
Causes RAID Manager to wait for the specified time.sleep
Deletes the specified environment variable(s).usetenv
The following table describes the Windows subcommands. The RAID Manager software provides
subcommands for the Windows platforms that are executed as options (-x <command> <arg>) of
another command.
Table 4 Windows subcommands
DescriptionSubcommand
Displays the relationship between the disk numbers assigned by the Windows system and
the LDEVs on the RAID storage system, and also displays attribute and status information
for each LDEV.
drivescan
Searches for command devices within the specified range of disk drive numbers. If it is
found, the command device appears in the same format as in the configuration definition
findcmddev
file. This subcommand is used when the command device name is not known and when
the HORCM is not started.
Mounts the specified drive to the specified partition on the specified hard disk drive using
the drive letter. When the mount subcommand is executed without an argument, all currently
mount
mounted drives (including directory mounted volumes) are displayed, and logical drive has
been mounting an LDM volume then displays Harddisk#[n] configured an LDM volume.
Displays the devices on the specified port(s).portscan
The sync (synchronization) Windows subcommand sends unwritten data remaining on the
Windows server to the specified device(s) to synchronize the pair(s) before the RAID
Manager command is executed.
sync and syncd
The syncd (sync delay) Windows subcommand waits the delayed IO for dismount after
issued sync.
umount and umountd
The following table describes the configuration setting commands (raidcom commands).
Table 5 Configuration setting commands
DescriptionCommand
Creates a host group.raidcom add host_grp
Deletes a host group.raidcom delete host_grp
Sets the host mode.raidcom modify host_grp
14 Overview of commands