HP P9000 RAID Manager Reference Guide (T1610-96037, October 2011)

Options and parameters
DescriptionOption
Specifies the number of the port whose attribute is “ELUN(External).-port <port>
For example:
CL1-A
Displays an external port.
Examples
Displaying the external storage system ports from the port: CL1-A.
# raidcom discover external_storage -port CL1-A
PORT WWN PM USED Serial# VENDOR_ID PRODUCT_ID
CL1-A 50060e8005fa0f36 M YES 60010 HP P9500
CL1-A 50060e8005fa0f38 M YES 60010 HP P9500
Description on each column in output example
PORT
This displays the P9500 external port number.
WWN
This displays the WWN which can be referred to from the port.
PM
This displays the path mode for external path.
M: Multi, S: Single, A: APLB
USED
This displays whether this target WWN is used or not.
YES: Used, NO: Not used
Serial#
Product serial number of the external storage system.
VENDOR_ID
This displays the VENDOR_ID of the external storage system.
“OTHER” is displayed if an unsupported external storage system is connected.
PRODUCT_ID
This displays the PRODUCT_ID of the external storage system.
“OTHER” is displayed if an unsupported external storage system is connected.
raidcom add host_grp
Creates a host group to the specified port.
If the specified port does not exist, it will be rejected with EX_ENOOBJ.
If the specified port/host group already exists, it will be overwritten by the specified host group
name.
The specified host group name must be unique in a port.
Syntax
raidcom add host_grp -port <port> -host_grp_name <host group name>
raidcom add host_grp 129