Upgrading a VA 7100/7400to a VA 7410/7110 - Upgrade Instructions
10 Upgrading a VA 7100/7400 to a VA 7410/7110
Step 12. Format the array controller enclosure
Skip this step because the array has already been formatted.
Step 19. Build the Host Port Behavior Table
The host port behavior table is stored on the array mid-plane and it should not
be necessary to recreate the table. However, it is recommended that you read
the table from the array and check it to make sure it contains the proper
entries. Use the following command to read the table to the file identified by
filename:
armhost -r -f filename array-id
Step 21. Build the Secure Manager LUN Security Table
If the Secure Manager LUN security table was saved from the original array,
use the configuration information to restore the LUN security table. Use the
following command to write the LUN security table to the array from the file
saved earlier:
armsecure -w -f armsecure_<array_id>.txt -p password
<array_id>
Restore Array Data
After the LUN configuration has been restored, the data can be restored from
the backup medium.