Appendix A. Disk Array Controller Log
Event
Number
(dec/hex)
Event
Name
Logged?
Predictive
Maintenance
Implication
Suspected
Components
Mfg Fail?
Description
is ErrEnR2. The tenth byte is ErrDR2.
381/0x17d
LCC Installed Y Ignore - Operator
Activity
LCC, Back End
FC Port,
Controller
N This error code indicates the system state change
consisting of an LCC hot plug insertion. The device
number of the drive added appears in this change
record. A device number consisting of the
controller serial number followed by a 0 indicates
that the device number has not yet been assigned.
382/0x17e
LCC Removed Y Ignore unless no
Operator activity
LCC, Back End
FC Port,
Controller
N This error code indicates the system state change
consisting of an LCC hot plug removal. The device
number of the lcc removed appears in this change
record. A device number consisting of the
controller serial number followed by a 0 indicates
that the device number has not yet been assigned.
383/0x17f
DDM failed image disks Y Ignore unless no
Operator activity
disk drives N This error code indicates the system could find a
usable image disk to reload NVRAM from at system
start up.
384/0x180
Battery charger firmware
downloader status
Y battery charger N This event is used to report status related to the
battery charger firmware download process. See the
extended event info field for the actual status.
385/0x181
Failure in TWSI Driver module Y Controller,
battery, power
supply,
midplane
Y 2C_DRIVER_FAILURE This error indicates that an
attempt to communicate with a two-wire serial
device has failed, possibly after multiple retries.
386/0x182
VSC7130 chip failed Y VSC7130
Signal Detect /
Port Bypass
Control chip
Y The VSC7130 chip used for FC signal detect and
port-bypass control has suffered a hardware failure.
There is a VSC7130 for the host port and one for the
JBOD port. This will result in the controller being
failed. See extended information for which 7130
failed.
387/0x183
Internal drive inserted Y Disk internal to
the controller
enclosure
N An internal disk has been inserted into the
enclosure.
388/0x184
Internal drive removed Y Disk internal to
the controller
enclosure
N An internal disk has been removed from the
enclosure.
389/0x185
Internal drive requesting port
bypass
Y Disk internal to
the controller
enclosure
N An internal disk is requested that its FC port be
bypassed.
390/0x186
Internal drive has stopped
requesting port bypass
Y Disk internal to
the controller
enclosure
N An internal disk has stopped requesting that its FC
port be bypassed.
391/0x187
Internal drive is indicating a
fault
Y Disk internal to
the controller
enclosure
N An internal disk is indicating that it is faulted.
392/0x188
Internal drive is no longer
indicating a fault
Y Disk internal to
the controller
enclosure
N An internal disk is no longer indicating that it is
faulted.
393/0x189
No GBIC Installed Y GBIC port N No GBIC is installed on this controller
394/0x18a
GBIC of type MOD DEF 4
Installed
Y GBIC port N A GBIC has been inserted on this controller
395/0x18b
GBIC of type Mod Def 4
Removed
Y GBIC port N A GBIC has been removed from this controller
396/0x18c
GBIC Transmit Fault Y GBIC port N The GBIC is indicating a transmit fault
397/0x18d
GBIC no longer indicating
Transmit Fault
Y GBIC port N The GBIC is no longer indicating a transmit fault
398/0x18e
GBIC Receive Signal Lost Y GBIC port N The GBIC is indicating that the no receive signal is
present
399/0x18f
GBIC no longer indicating
Receive Signal Lost
Y GBIC port N The GBIC is no longer indicating that the no receive
signal is present
400/0x190
Non-Mod Def 4 GBIC
Installed
Y GBIC port Y A non-Module Definition 4 type GBIC has been
installed. This GBIC type is not supported and will
be disabled. This GBIC will also be marked as
failed.
401/0x191
Non-Mod Def 4 GBIC
Removed
Y GBIC port N A non-Module Definition 4 type GBIC has been
installed. This GBIC type is not supported but will
be used anyway.
402/0x192
GBIC EEPROM has failed Y GBIC Y Unable to communicate with the EEPROM on the
GBIC. The EEPROM must be failed.
403/0x193
JBOD FC Signal Detected Y JBOD Port N An FC signal is now detected on the JBOD port.
404/0x194
JBOD FC Signal Lost Y JBOD Port N An FC signal is no longer detected on the JBOD