Using VADIAG on HP-UX
SETOPTIONS 27
Using VADIAG on HP-UX
SETOPTIONS
View and modify SCSI Mode parameters.
Syntax
setoptions
Description
This command returns SCSI mode sense parameters on the selected array and enables you to
modify changeable parameters.
Example
VADIAG> setoptions
Parameter information for ArrayIndex 0
Select the number of the parameter to modify.[Return quits]:
Subsystem Parameter Value Subsystem Parameter Value
------------------------------- ------- -------------------------------- -------
1 Subsystem State Ready 17 Reserved 0
2 Overcommit Enabled OFF 18 Controller 1 Port 0 Loop ID 107
3 Host Spare Desired OFF 19 Reserved 0
4 Part OFF 20 Enable Manual Override OFF
5 Rebuild in Progress OFF 21 Manual Override Destination OFF
6 Auto-Rebuild ON 22 Embedded Processor Download OFF
7 Auto-Include ON 23 Language English
8 Balance in Progress OFF 24 Capacity Depletion Threshold 0
9 Optimize in Progress OFF 25 Reserved 0
10 Migrating Write Destination OFF 26 Write Working Set Interval 8640
11 LUN Security Enabled OFF 27 Subsystem Identifier 1
12 Rebuild Priority ON 28 Rebuild Progress 0
13 Cntrl Download in Progress OFF 29 Reserved 0
14 Shutdown Completion Control OFF 30 Microcode Download Progress 0
15 Unit Attention ON 31 Cntrl 0 Host Port Behavior 1
16 Controller 0 Port 0 Loop ID 109 32 Cntrl 1 Host Port Behavior 1