Using VADIAG on HP-UX

DISPVOLSET 11
Using VADIAG on HP-UX
DISPVOLSET
Displays internal disk volume set serial number.
Syntax
dispvolset
Description
This command displays a table that includes the internal disk’s FRU, storage type, state, firmware
revision, capacity, and volume set serial number. The storage type (Map/User column) indicates if
the disk is used for user data storage (US), meta data storage (MS) (Map Disk), or both.
Example
VADIAG> dispvolset
Fru
Map/
User Drive State Rev Capacity
Volume Set
Serial Number
------ ----- --------------- ----- ----------- -------------------
M/D7 US/MS Included HPK0 34179 MB 000004F60000002A
M/D8 US/MS Included HPK1 17089 MB 000004F60000002A
M/D12 US Included HPK1 17089 MB 000004F60000002A
M/D3 US Included HPK1 17089 MB 000004F60000002A
M/D4 US Included HPC2 17089 MB 000004F60000002A
M/D5 US Included HPK0 34179 MB 000004F60000002A
M/D6 US Included HPK0 34179 MB 000004F60000002A