Storage Mirroring User Guide
13 - 16
DTCounters 1004 Error The Double-Take counter DLL could not
read the "First Counter" value under the
Double-Take\Performance Key.
Run the Storage Mirroring installation and
select Repair. Contact technical support if
this event occurs again.
1005 Error The Double-Take counter DLL read the
"First Help" value under the
Double-Take\Performance Key.
Run the Storage Mirroring installation and
select Repair. Contact technical support if
this event occurs again.
1006 Error The Double-Take counter DLL could not
create event handler for the worker
thread.
Run the Storage Mirroring installation and
select Repair. Contact technical support if
this event occurs again.
Failback 5200 Info Failback completed for %1. No action required.
5201 Info IP address %1 was removed from target
machine's %2 adapter.
No action required.
5202 Error Unable to Failback properly because IP
address %1 was missing a corresponding
SubNet Mask.
Contact technical support.
Failover 5100 Info Failover completed for %1. No action required.
5101 Info IP address %1 with subnet mask %2 was
added to target machine's %3 adapter.
No action required.
5102 Warning %1 has reached a failover condition. A
response from the user is required before
failover can take place.
User intervention has been configured.
Open the Failover Control Center and
accept or decline the failover prompt.
5103 Info Started adding drive shares from %1 to
%2.
No action required.
5104 Info %1 drive shares were taken over by %2. No action required.
5105 Info Attempting to run the %1 script. No action required.
5106 Success The %1 script ran successfully. No action required.
5107 Error Error occurred in running %1 script. Verify that the script identified exists with
the proper permissions.
5108 Error The source machine %1 is not responding
to a ping.
This occurs when all monitored IP
addresses on the source machine stop
responding to pings. Countdown to
failover will begin at the first occurrence
and will continue until the source machine
responds or until failover occurs.
5109 Error The public NIC on source machine %1 is
not responding to a ping.
The failover target did not receive an
answer to its ping of the source machine.
Eventually, a failover will result.
Investigate possible errors (down server,
network error, etc.).
Monitoring 5300 Info The following IP address was added to
target's monitoring list: %1
No action required.
5301 Info The following IP address was removed
from target's monitoring list: %1
No action required.
5302 Info Drive share information for %1 has been
updated on the target machine.
No action required.
NSIPHDriver 9000 Error Could not allocate memory for storing
registry path
Reboot the server and contact technical
support if this event occurs again.
9001 Error Thread creation failed Reboot the server and contact technical
support if this event occurs again.
Category ID Severity Message Required Response