HP StorageWorks Storage Mirroring Recover Scripting Guide (T5437-96022, November 2010)
TGWriteCache
Description—Specifies whether or not Storage Mirroring Recover uses
the intermediate cache
Values—0 Bypass the intermediate cache and write directly to disk, 1 Do
not bypass the intermediate cache
Default—1
GUI Setting—None
Service restart required—No
TGWriteFailureBeforeNotification
Description—Specifies the number of times an operation will be retried
on the target before a notification is sent to the source to update the Target
Status field of the Management Console.
Values—0-1024
Default—10
GUI Setting—None
Service restart required—Yes
Notes—If you change the setting to 0, the notification will be disabled.
Changing this option will only affect how the status is changed on the
Target Status field of the Management Console. To solve the underlying
issue of why the operations are failing will require investigation into the
Storage Mirroring Recover log files.
UpdateInterval
Description—Interval, in seconds, at which the Failover Control Center
updates the monitored machines display
Values—1 - 9999
Default—1
GUI Setting—Failover Control Center, Settings, Refresh Rate
Service restart required—No
UpgradeCode
Description—Used by the Storage Mirroring Recover installation program
to maintain the installation settings for an upgrade. Do not modify this
entry.