HP StorageWorks Storage Mirroring Recover Scripting Guide (T5437-96022, November 2010)

OpBuffersCount
Description—An internal setting for memory buffering. Do not modify this
setting.
OpLogging
Description—Specifies whether operations from the Storage Mirroring
Recover driver are logged
Values—0 Do not log operations, 1 Log operations
Default—0
GUI Setting—None
Service restart required—Yes
OutOfOrderDiff
Description—The maximum number of operations that can be out of
order before the connection is paused
Values—any integer
Default—10
GUI Setting—None
Service restart required—No
Notes—The larger the value, the more memory the Storage Mirroring
service on the targe service will use.
PingFrequency
Description—Specifies, in seconds, how often a ping is sent to the
source from a monitoring target
Values—1 - 65535
Default—5
GUI Setting—Failover Control Center, Monitor Settings, Monitor Interval
Service restart required—No
Port
Description—Port connection for core Storage Mirroring Recover
communications
Values—1025 - 65535
Default—6320