HP StorageWorks Scalable File Share System Installation and Upgrade Guide Version 2.2

Installing the servers — EVA4000 storage6–30
3. Start the MDS server again by entering the command shown in the following example:
sfs> boot server south2
4. Enter the command shown in the following example:
sfs> configure server south2
5. If the MDS server is a ProLiant DL G4 server, skip this step.
If the MDS server is a ProLiant DL G3 server, reboot the MDS server by entering the following
commands on the administration server:
sfs> shutdown server south2
sfs> boot server south2
Proceed to Section 6.15.3 to verify the installation of the MDS server.
6.15.3 Verifying the installation of the MDS server
To verify the installation of the MDS server, perform the following steps:
1. Connect to the console of the MDS server and log in as the root user.
2. Run the following tests:
a. Verify that the site network is operating correctly, by ensuring that you can ping other hosts on
the site network from the MDS server, and that you can ping the MDS server from hosts on the
site network.
b. Verify that the date on the MDS server, as served by the NTP server specified earlier, is correct.
c. Verify that the server is running correctly, by entering the command shown in the following
example. If the MDS server is running correctly, the parameter values will be as shown in
Table 6-2:
# sfsmgr
.
.
.
sfs> show server south2
Name: south2
Primary Role: mds
Backup Server: south1
Server Firmware Model: 29
Server Firmware Date: 05/01/2004
iLO Firmware: 1.82
Current Config. State: Configured
Desired Config. State: Configured
Status: Finished
State: running
Power: on
Server Enabled: yes
Primary Services:
Running Services: none
.
.
.
Table 6-2 shows the values that are displayed when the MDS server is running correctly.