HP Scalable File Share G3 MSA2000fc How To

7 Shutting down and restarting controllers
You can restart processors in a controller module when SMU indicates a changed configuration
setting that requires restarting or when the controller is not working properly. Shut down the
processors in a controller module before you remove it from an enclosure or before you power off
the enclosure for maintenance, repair, or a move. You can perform a restart on either the SC
processor or the MC processor. A shutdown affects both SC and MC processors.
7.1 Restarting
When restarting the SC, a shutdown is attempted with a proper failover sequence including stopping
all I/O operations and flushing the write cache to disk before the controller restarts. The MC is not
restarted because it provides status information to external interfaces. If you restart a MC,
communication with it is lost until it successfully restarts. If the restart fails, the partner MC remains
active with full ownership of operations and configuration information.
CAUTION: If you restart both controller modules at the same time, access to the system and data
is lost until the restart is complete.
7.1.1 Restarting MSA2212fc array controllers
1. Select ManageRestart SystemShut Down/Restart.
2. In the Restart Controller panel, select a controller option.
3. Click Restart. A confirmation prompt appears.
4. Click OK to confirm the operation, or Cancel to stop it. If you click OK, a message indicates
if the operation succeeded.
7.1.2 Restarting MSA2312fc array controllers
1. In the Configuration View panel, right-click the local system and select ConfigurationShut
Down or Restart Controller.
2. In the main panel, set the following options:
Select the Restart operation.
Select the type of controller processor to restart.
Select whether to restart the processor in controller A, B, or both.
3. Click Restart now. A confirmation dialog appears.
4. Click Yes to continue. Otherwise, click No. If you click Yes, a second confirmation dialog
appears.
5. Click Yes to continue. Otherwise, click No. If you click Yes, a message describes restart
activity.
7.2 Shutting down
Shutting down the SC in a controller module ensures a proper failover sequence, including stopping
all I/O operations and writing to disk any data in write cache. If the SC in both controller modules
is shut down, hosts cannot access the system data. Perform a shutdown before removing a controller
module or powering down the system.
18 Shutting down and restarting controllers