HP Scalable File Share G3 MSA2000fc How To

10. Start a new Telnet session on controller A as a manage user. To verify the firmware versions:
# versions
Output for MSA2212fc :
Controller A Versions
---------------------
Storage Controller CPU Type : Pentium-III 700MHz
Storage Controller Firmware : J200P46
Storage Controller Memory : F300R22
Storage Controller Loader : 15.010
Management Controller Firmware: W420R58
Management Controller Loader : 12.013
Expander Controller Firmware : 3206
CPLD Revision : 27
Hardware Revision : LCA 56
Host Interface Module : 26
Host Interface Module Model : 1
Output for MSA2312fc:
Controller A Versions
---------------------
Storage Controller CPU Type: Sempron 3000+ 1800MHz
Storage Controller Code Version: M110R28
Memory Controller FPGA Code Version: F300R22
Storage Controller Loader Code Version: 19.009
Management Controller Code Version: W441R13
Management Controller Loader Code Version: 12.015
Expander Controller Code Version: 1106
CPLD Code Version: 8
Hardware Version: 50
Host Interface Module Version: 50
Host Interface Module Model: 0
If the controller displays the appropriate versions for all firmware components, the code load
is successful.
11. After confirming the upgrade of controller firmware on controller A is successful, log in to
controller B. Upgrade the controller firmware on controller B by performing steps 3 to 10.
12. After all controller pairs in all MSA CEs are upgraded to the appropriate firmware level, start
all HP SFS servers and file system components (MGT, MDT, and OSTSs). For more information,
see section 5.3 Starting the File System in the HP Scalable File Share User Guide G3.2-0.
3.5 Upgrading controller firmware (J200*.bin) using FTP and CLI interface for MSA2212fc and MSA2312fc 11