RAID Array 3000 Firmware Upgrade Procedure
12. At 9600 baud, the download will take between 45 to 60 minutes. At 38400, it should take around 10
to 12 minutes. At completion, you will see the "FLASH Programming complete" message followed
by the FLASH Boot Utility Options menu again.
13. Select item (9), Restart Controller. The system displays a request message to reset the baud rate
back to 9600. Use the HyperTerminal File | Properties | Configure menu to reset the baud rate to
9600. You may have to disconnect and connect the HyperTerminal session. Press the Return key
after HyperTerminal restarts.
14. The system will display the FLASH Boot Utility Options menu again. Your firmware will now be
upgraded.
StorageWorks Command Console Method
For more details on how to use SWCC refer to Command Console for RA3000. This file is also located on
the CD in \Docs directory and is named SWCC_UG.pdf.
1. Stop all I/O to RAIDset
2. Go into SWCC HSZ22 storage window
3. Click on Storage
4. Click on Controller
5. Click on Update Firmware
6. Click on Browse in the Update Firmware window
7. Go to directory where the firmware is located
8. Get file with the FDI extension (example: D11x.fdi)
9. Click on Start Update
10. Will get window stating "Firmware update in progress, Please wait."
11. Upon completion, verify the firmware version, by clicking on the Controller Icon displayed in the
GUI and look under General tab