XPInfo v19.00.00 release notes (T1798-96302, March 2010)
• Window: HP DSM v2.00.02
• HP-UX
• HP-UX 11.31: Native multipathing
• Earlier versions of HP-UX: Secure Path 3.0F.02F.02F.patch
• Linux: HDLM 5.9.3.01 and VERITAS Storage Foundation 5.0
Firmware requirements
Table 1 describes the minimum firmware requirements.
Table 1 Firmware requirements
Minimum requirementXP Array
60.01.31.00/00XP24000
60.01.66.00/00XP20000
50.07.69.00/00SVS200
50.09.34.00/00XP12000
50.09.34.00/00XP10000
21.14.30.00/00XP128, XP1024
01.19.99.00/02XP512, XP48
V01.13.00
For XP Performance Advisor Advanced Interactive eXecutive
(AIX) host agent, the RMLIB version is V01.14.02
RAID Manager Library (RMLIB) when used with
the XP24000, XP12000, XP10000, and SVS200
disk arrays
Enhancements
XPInfo 19.00.00 includes the following enhancement:
XPInfo –D creates the Xpinfo.log file that will have all the debug statements printed in the log
file.
Fixes
XPInfo 19.00.00 includes the following fixes:
• The disk mechanics information for XP24000, XP12000, and XP10000 disk arrays with RAID 6
support is now displayed correctly for AIX host agents.
• The disk mechanics information for XP20000 Disk Array with RAID 6 support is now displayed
correctly on Windows and non-windows host agents.
• CHIP Utilization reports are now properly generated for XP20000 disk arrays.
• An error log does not appear now on the console of the AIX host agent in the following condition
or when you execute errpt –a from the Kernel of the AIX operating system:
• XPInfo is active on AIX v5.2 or later
• Multi-pathing (MPIO) is enabled on the AIX host agent
4