HP XPInfo V28.00.00 Release Notes

ESXi 5.0
ESXi 5.1
NOTE: Multipathing is enabled.
Firmware requirements
Table 1 (page 5) lists the minimum firmware requirements.
Table 1 Firmware requirements
Minimum firmware versionXP and XP7 disk arrays
80-01-22-00/02XP7
60-04-13-00/00 to 60-08-43-00/00XP24000
60-02-48-00/12 to 60-08-43-00/00XP20000
50.07.69.00/00 or laterSVS200
50.09.34.00/00 or laterXP10000/XP12000
70-05-02-00/00 to 70-06-13-00/00P9500
Update RMLIB version to 1.19.00 or laterXP7/XP RAID Manager Library (RMLIB) XP24000,
XP12000, XP10000, and SVS200)
NOTE: HP XP7 Performance Advisor v6.1 supports all the hard disks that are supported by XP
and XP7 disk arrays. HP recommends that you install or upgrade to the latest RMLIB version to
obtain the new features.
New features
HP XPInfo new features include the following:
HP XPInfo supports XP7 disk arrays.
For XP7 disk arrays, the disc mechanics are displayed as similar to Performance Advisor.
HP XPInfo is supported on SUSE Linux Enterprise Server (SLES) 11 SP3 and RHEL 6 update 5.
Enhancements
Support is added for new platforms. For more information, see HP XP7 Performance Advisor
Software OS Support Matrix available on the HP XP7 Performance Advisor Software page.
NOTE: To understand the features and usage of HP XPInfo, use the xpinfo -h option.
Fixes
HP XPInfo v28.00.00 includes the following fixes:
XP7 disk arrays do not support online data migration. Therefore, HP XPInfo does not display
the migrated volumes.
Notes
HP XPInfo does not display any value for the SLPR parameter. This is applicable only for P9500
and XP7 disk arrays.
xpinfo -V is not supported on IBM AIX and OpenVMS operating systems.
ODX feature is supported only on Windows operating systems
Firmware requirements 5