HP XP7 Performance Advisor v6.1 Software Troubleshooting and FAQs Guide
The dashboard high watermark is disabled, if you select multiple resources and plot their
performance graphs for different metrics. The dashboard high watermark is displayed only when
you select a single resource and metric combination.
Why is the dashboard high watermark not displayed for LDEVs?
The dashboard high watermark is not displayed for LDEVs, because there is no option to set the
threshold values for LDEVs on the Threshold Settings screen.
What does X icon beside a resource indicate in the Statistics section on the Dashboard screen?
The X icon beside a resource in the Statistics section indicates that the utilization of that resource
corresponding to a particular metric is beyond the set threshold limit.
After an upgrade, when I log in to HP XP7 Performance Advisor, the Dashboard displays the error
message Error getting XP Array Health.
This error is displayed because the performance threshold values are not yet set. For more
information on setting threshold values, see the HP XP7 Performance Advisor Software User Guide.
From HP XP7 Performance Advisor v4.6 onwards, default threshold values are already provided
for the following metrics:
• CHA Util (%) – 70%
• Write Pending (%) – 28%
• DKA Util (%) – 70%
• RG Util (%) – 50%
From HP XP7 Performance Advisor v5.0 onwards, default threshold value is also provided for the
MP blade Util (%) metric (applicable only for XP7 disk arrays), which is 70%.
In addition to providing the threshold values for the other Frontend, Cache, Backend, and MP
blade metrics, you can retain the default values or provide values of your choice for the above
mentioned metrics. The status of resources for the above mentioned metrics is derived based on
the default or threshold values that you set, and displayed on the Troubleshooting screen.
Configuration and performance data collections
When IOs are running on command device, the following exception is seen and DKC performance
collection stops:Exception in thread "MP Busy collector - 310003"
java.lang.ArrayIndexOutOfBoundsException
Stop the I/O activity on the command devices.
After a configuration data collection, the last collection time stamp in the Array View screen is not
updated. Why?
The last collection time stamp is not updated for a configuration data collection. Only a confirmatory
message indicating a successful configuration data collection is displayed in the Event Log screen.
However, if you initiate a performance data collection, the last collection time stamp is updated
once the frequency of collection for the individual resources is complete. For example, if a
performance data collection is initiated at 9:47 AM for a frequency of 5 minutes, the last collection
time stamp is updated only after the 5 minutes completes.
I have added a command device from SLPR1. Can I collect information through that command
device for LUNs presented through other SLPRs?
No. If you add a command device from SLPR1, that command device collects information only for
the LUNs presented through SLPR1. However, if you add a command device from SLPR0, it collects
data from all the LUNs presented through SLPR0. In addition, the command device also collects
data from LUNs presented through associated SLPRs, such as SLPR1, and SLPR2.
I've set the frequency of collection as 5, 10, and 15 minutes for DKC, port, and RAID groups. The
DKC time stamp is getting updated while I am observing that the port time stamp is not getting
updated. Why?
Configuration and performance data collections 61