HP XP7 Performance Advisor Software 6.1 Command-line User Interface Reference Guide

Enables you to obtain Pool occupancy and Pool capacity metrics for the ThP and smart pools.
Switches
Required. Specify the array serial number.–dkc <serial #>
Specify the THP pool ID for which you want output displayed.–pid <thp pool id>
Specify the address of a management station in the format <http://
path.to.managementstation:<port>> or <https://
path.to.managementstation>.
–ms <URL>
Specify a user name and password pair in the format user name:password.–auth <user:passwd>
Can be used in place of -auth.
NOTE: The password file must be created using the encrypt command only.
–pf <password file>
Specify the delimiter for delimited display.–d <char>
Displays readable output.–hr
Prints the usage statement.–?
Specify the start time in the format mm.dd.yyyy hh:mm:ss.–st <mm.dd.yyyy
hh:mm:ss>
Specify the end time in the format mm.dd.yyyy hh:mm:ss.—et <mm.dd.yyyy
hh:mm:ss>
NOTE:
The -st and et options are supported with the pid option only. The array serial number
and dkc are required elements.
The thp command takes ThP and smart pool id as input and displays values for the configured
ThP and smart pool performance and capacity metrics.
Examples
thp -dkc 53036
thp -dkc 53036 -hr
thp -dkc 53036 -pid 25
thp -dkc 53036 -pid 25 -hr
thp -dkc 53036 -pid 0 -hr
SNAPSHOT
Syntax
snapshot -dkc <serial #> [-pid <snapshot pool id>] [-auth <user:passwd>]
[-ms <URL>] [-L] [-d<char>] [-hr] [-?] [-pf <password file>]
Supported disk array types
XP, P9000 and XP7 disk arrays
Description
Enables you to obtain Snapshot pool related information. This command provides the Snapshot
pool occupancy value in percentage. This command does not display the snapshot pools unless
snapshot pool is associated with any Virtual volume.
40 CLUI commands