HP StorageWorks XP Performance Advisor Software v4.6 User and Troubleshooting Guide (T1789-96094, June 2010)
5. Click Update Records to save the changes.
After the records are saved, the updated information is displayed on all the relevant XP
Performance Advisor screens.
Deleting fabricated LDEV records
To delete a fabricated LDEV record:
1. Click Settings in the left pane.
2. Select Data Grid Update.
The Data Grid Update screen appears.
3. In the Data Grid Update table, select the check boxes for those LDEV records that should be
deleted.
Alternatively, use the Data Grid Update filters to search for LDEV records that match the specified
filter criteria.
4. Click Delete Records.
A dialog box appears prompting you to confirm the removal of the selected LDEV records.
5. Click OK.
The record is removed from the existing list of records.
Related topics
See the following related topics:
• “Querying for fabricated LDEV records” on page 90
• “Applying Template” on page 93
Using template
IMPORTANT:
• Ensure that the LDEV record used as a template is immediately preceding the other set of LDEV
records.
• The Targent:LUN and Device File data cannot be replicated across LDEV records. You must
manually modify the LDEV records to update these details.
To replicate values from an LDEV record across other LDEV records:
1. Click Settings in the left pane.
2. Select Data Grid Update.
The Data Grid Update screen appears.
3. Select the check box for the LDEV record that should be used as a template.
HP StorageWorks XP Performance Advisor Software User Guide 93