HP StorageWorks XP Performance Advisor Software v4.6 User and Troubleshooting Guide (T1789-96094, June 2010)

IMPORTANT:
The LUSE resources that are fabricated internally are not displayed. Use XP Performance Advisor
Command Line User Interface (CLUI) to modify such LUSE resources.
Editing fabricated LDEV records
To edit a fabricated LDEV record:
1. Click Settings in the left pane.
2. Select Data Grid Update.
The Data Grid Update screen appears.
3. Select the check box for the LDEV record that you want to edit.
4. Enter values for the following in the text boxes located above the Data Grid Update table:
Host
Target:LUN
Volume Group
Device File
SSID
Alternatively, click in the text boxes under the respective column headings in the Data Grid Update
table and make the necessary changes.
NOTE:
If you enter values in the text boxes (see step 4) and also in the Data Grid Update table text
boxes, XP Performance Advisor considers the values entered in the text boxes above the list
of LDEV records.
IMPORTANT:
The following fields are checked against criteria:
Target:LUN: Target >=0 and <=128, LUN >=0 and <=2048.
SSID: >=-1 and <=256.
If a value -1 is displayed in any of the columns, you may want to edit the column and submit
it to the database.
Configuring common settings for XP Performance Advisor92