HP StorageWorks XP Performance Advisor Software v4.6 User and Troubleshooting Guide (T1789-96094, June 2010)

1. THP, Snapshot, XP Continuous Access Journal volumes, or External RAID groups are not selected
from the respective resource type lists.
2. The Add new RAID Groups, Ports to this schedule check box is selected.
After the settings are saved, the following changes occur:
Only the newly discovered RAID groups and ports are automatically added to this performance
data collection schedule, as the Add new RAID Groups, Ports to this schedule check box is selected.
New virtual volumes are not added to this schedule, as it is not collecting performance data for
virtual volumes.
The RAID groups, ports, and virtual volumes that were not selected from the respective resource
type lists are automatically added to the second schedule when it is created.
New virtual volumes are automatically added to the second schedule even if the Add new RAID
Groups, Ports to this schedule check box is not selected in the second schedule. These resources
cannot be split across schedules.
If a second schedule is not created, the existing list of RAID groups, ports, and virtual volumes are
still available for selection in the first schedule. You must modify the first schedule if you want to
add these resources to the existing list. For more information on editing a performance data col-
lection schedule, see Editing frequency of performance data collection on page 59.
Scenario 3
While creating a performance data collection schedule:
1. RAID groups, ports, and virtual volumes are selected from the respective resource type lists.
2. The Add new RAID Groups, Ports to this schedule check box is not selected.
After the schedule settings are saved, the following changes occur:
The performance data collection is initiated only for the selected list of resources.
New virtual volumes are automatically added to the first schedule even if the Add new RAID
Groups, Ports to this schedule check box is not selected in the first schedule. These resources
cannot be split across schedules.
The newly discovered RAID groups and ports are not added to this performance schedule, as the
Add new RAID Groups, Ports to this schedule check box is not selected. However, if a second
schedule is created, you can still select the Add new RAID Groups, Ports to this schedule check
box. The new RAID groups and ports are automatically added to the second schedule.
If a second schedule is not created, the list of new RAID groups and ports are still available for
selection in the first schedule. You must modify the first schedule if you want to add these resources
to the existing list.
Scenario 4
While creating a performance data collection schedule:
1. The existing RAID groups and ports are not selected from the respective resource type lists.
2. The Add new RAID Groups, Ports to this schedule check box is also not selected.
After the schedule settings are saved, for the above mentioned scenario, the following changes occur:
The new RAID groups and ports are not added to the existing schedule. If a second schedule is
created and the Auto Update check box is selected, the existing and new RAID groups and ports
are automatically added to the second schedule.
If a second schedule is not created, the list of new and existing RAID groups and ports are still
available for selection in the first schedule. You should modify the first schedule if you want to add
these resources to the existing list.
Collecting configuration and performance data58