5. Retain the Collection Type as OutBand (default selection), if you want XP Performance Advisor to
directly collect data from an XP array through its SVP. The IP Address is automatically displayed
for an XP array, if you have already registered the SVP with the respective management station.
You can also manually enter the SVP IP address.
Select the Collection Type as Inband, if you want RAID Manager Library (RMLib) to collect
configuration data from an XP array, and transfer to XP Performance Advisor. The Inband mode
of configuration data collection is supported for the XP1024/128, XP10000, XP12000, XP20000,
and XP24000 disk arrays.
IMPORTANT:
Outband is the preferred mode of configuration data collection for an XP Disk Array of type
XP10000, XP12000, XP20000, or XP24000. If the SVP on the XP Disk Array is accessible,
HP recommends that you use the Outband mode of configuration data collection, as XP
Performance Advisor receives the accurate internal raw disk capacity from the XP Disk Array
(same as shown by RWC) through the Outband mode. Collect configuration data through
the Inband mode for an XP Disk Array only if Outband mode of configuration data collection
is not supported on that array.
6. Click Submit.
XP Performance Advisor starts collecting configuration data for the XP array through the selected
command device. The Collection Status displays the message, In progress...please wait for that XP
array. After the configuration data is collected, the Collection Status shows Done. The Last Collection
displays the updated time stamp, when XP Performance Advisor completes receiving the latest
configuration data.
Clicking Reset restores the default settings.
Related Topics
See the following related topics:
Scheduling configuration data collection on page 46
Deleting configuration data collection schedules on page 49
Performance data on page 50
Providing user-friendly names for XP arrays on page 80
Registering the XP array SVP IP address in XP Performance Advisor on page 80
Filtering event records on page 145
Configuring email and SNMP settings on page 76
Starting real-time performance data collection on page 67
Viewing performance summary for the XP array on page 176
Plotting charts on page 213
Scheduling configuration data collection
IMPORTANT:
The schedule start time is set to the management station time where XP Performance Advisor is installed.
Prerequisites
Collecting configuration and performance data46